ANALYTIC PIPE GmbH
Radberg 8
49808 Lingen
Germany
Phone: +49 591-71009-0
Fax : +49 591-71009-20
|
|
|
Magnetic Flux Leakage technology:
+ High resolution
+ Operational in any product
+ Reasonable costs
+ State of the art technology |
|
|
Circulation of magnetic field in the contour consisting of
pipeline wall material and constant magnet is disturbed by
any pipeline wall features and the deviation of magnetic
flux leakage (MFL) can be detected and measured by special
sensors.
|
|
|
MFL DETECTION CAPABILITIES:
- General corrosion
- Pitting
- Grooving
- Welds
- Hard spots
- Metal construct elements
- Magnets
- External excess metal objects
- T-pieces, flanges, valves, casing etc. |
 |
|
 |
MFL TECHNOLOGY TO GET ERF
(ESTIMATED REPAIR FACTOR)
DATA:
- MFL data is not a direct measure-
ment, so complex data interpretation
is required to transform flux leakage
into depth, width and length of
features.
- Discrimination between internal and
external features.
- Signal depends on length-to-width
ratio of features, limited ability on
narrow axial features.
- Results may be affected by pipe steel
characteristics, external objects and
stress in pipe walls. |
|
Available technologies in cooperation with partner:
- Video inspection
- Geometry inspection
- Ultrasound WM (wall thickness measurement) inspection
- Ultrasound CD (crack detection) inspection
- MFL (magnetic flux leakage) inspection
- Transverse Field MFL inspection
Analytic Pipe offers you offshore and onshore MFL survey
for any type of steel pipelines.
|
|
|
|